feat: developer tools page, auto-test orchestrator, BIP display, tests redesign
Bundles several feature streams that have been iterating on the working tree: - Developer Tools page (Debug-only via DEVELOPER_TOOLS symbol): hosts the identification card, manual KWP write + transaction log, ROM/EEPROM dump card with progress banner and completion message, persisted custom-commands library, persisted EEPROM passwords library. New service primitives: IKwpService.SendRawCustomAsync / ReadEepromAsync / ReadRomEepromAsync. Persistence mirrors the Clients XML pattern in two new files (custom_commands.xml, eeprom_passwords.xml). - Auto-test orchestrator (IAutoTestOrchestrator + AutoTestState): linear K-Line read -> unlock -> bench-on -> test sequence with snackbar UI and progress dialog VM, gated on dashboard alarms. - BIP-STATUS display: BipDisplayViewModel + BipDisplayView, RAM read at 0x0106 via IKwpService.ReadBipStatusAsync; status definitions in BipStatusDefinition. - Tests page redesign: TestSectionCard + PhaseTileView replacing the old TestPlanView/TestRunningView/TestDoneView/TestPreconditionsView/ TestSectionView controls and their VMs. - Pump command sliders: Fluent thick-track style with overhang thumb, click-anywhere-and-drag, mouse-wheel adjustment. - Window startup: app.manifest declares PerMonitorV2 DPI awareness, MainWindow installs a WM_GETMINMAXINFO hook in OnSourceInitialized and maximizes there (after the hook is in place) so the app fits the work area exactly on any display configuration. - Misc: PercentToPixelsConverter, seed_aliases.py one-shot pump-alias importer, tools/Import-BipStatus.ps1, kline_eeprom_spec.md and dump-functions reference docs. Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
This commit is contained in:
@@ -59,6 +59,9 @@ namespace HC_APTBS.Models
|
||||
/// <summary>Flasher relay toggle interval (ms).</summary>
|
||||
public int FlasherIntervalMs { get; set; } = 800;
|
||||
|
||||
/// <summary>RPM trend chart update rate on the Pump page (Hz). Drives a fixed-rate timer independent of value changes.</summary>
|
||||
public int RpmChartUpdateHz { get; set; } = 15;
|
||||
|
||||
// ── PID temperature controller ────────────────────────────────────────
|
||||
|
||||
/// <summary>Proportional gain.</summary>
|
||||
@@ -119,6 +122,16 @@ namespace HC_APTBS.Models
|
||||
/// <summary>When true, the T-in temperature sensor check is bypassed.</summary>
|
||||
public bool DefaultIgnoreTin { get; set; } = true;
|
||||
|
||||
// ── Auto Test ─────────────────────────────────────────────────────────
|
||||
|
||||
/// <summary>
|
||||
/// When true, the Dashboard "Connect & Auto Test" flow bypasses the oil-pump
|
||||
/// leak-check dialog. Operator accepts that responsibility up front by enabling
|
||||
/// this toggle. Does not affect the manual Bench page oil-pump toggle, which
|
||||
/// always shows the dialog.
|
||||
/// </summary>
|
||||
public bool AutoTestSkipsOilPumpConfirm { get; set; }
|
||||
|
||||
// ── Log rotation ──────────────────────────────────────────────────────
|
||||
|
||||
/// <summary>Number of daily log files to retain before the oldest is deleted.</summary>
|
||||
|
||||
Reference in New Issue