Charts
- Add faint background grid (0.75px, #E0E0E0) to all live charts; matches PDF report style
- Show min/max tolerance bands on P1/P2 pressure charts during test runs (previously only Q-Delivery/Q-Over)
- Broaden BenchService.ToleranceUpdated to fire for every phase receive; UI routes by name
- Clear P1/P2 traces on PhaseChanged alongside Delivery/Over
CAN
- Normalize QDelivery flow rate to 1000 RPM reference before IIR filter so RPM spikes are low-pass filtered with flow-rate transients (matches old_source behavior)
Pump page
- Reorder columns: identification left, commands center, live data right
- PreIn control always visible; disabled when pump lacks pre-injection (rename IsPreInVisible -> IsPreInAvailable)
- Swap value/label order in command cards
- Remove redundant KlineErrors row from identification card
Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
Unlock progress UI:
- UnlockProgressDialog with dark-themed progress ring, phase indicator, elapsed
time, and cancel/close buttons (non-modal, draggable borderless window)
- UnlockProgressViewModel with event-driven progress tracking via IUnlockService
- Triggers on pump selection (manual or K-Line auto-detect), not test start
UnlockService rewrite:
- Persistent CAN senders that outlive the unlock sequence (StopSenders on pump change)
- Concurrent K-Line fast unlock: awaits session Connected, sends RAM timer shortcut
({02 88 02 03 A8 01 00}), verifies via CAN TestUnlock before skipping wait
- Fix Type 1 verification (Value == 0 means unlocked, was inverted)
K-Line fast unlock support:
- IKwpService.TryFastUnlockAsync / KwpService implementation
Additional features:
- ILocalizationService with ES/EN resource dictionaries and runtime switching
- Safety dialogs: VoltageWarning, OilPumpConfirm, RpmSafetyWarning
- SettingsDialog for app configuration
- BenchService enhancements, ConfigurationService improvements, PDF report updates
- All UI strings localized via DynamicResource
Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
Restore the full bench control panel from the old source with MVVM architecture:
- Two-column left panel layout: bench info displays (RPM with target/voltage,
temps, pressures, Q-flow, pump live values) and user commands (direction
toggle, start/stop with RPM popup and quick-select buttons, oil pump toggle,
turn downcounter with CAN send)
- PID RPM ramp controller (BenchPidController) with bumpless startup,
anti-windup, and derivative-on-measurement for smooth motor speed transitions
- Real-time flowmeter charts (LiveChartsCore) for Q-Delivery and Q-Over
with tolerance band overlays
- Bench/pump CAN liveness detection in PcanAdapter (receive-only IDs)
- K-Line connection status indicator (placeholder)
- Periodic relay bitmask sender (~21ms) and ElectronicMsg keepalive start
on CAN connect, pump sender starts immediately on pump load
Fix critical CAN message ID bug: default bench XML values were incorrectly
converted from old source (decimal-notation hex parsed as actual hex digits,
e.g. "10" -> "A" instead of keeping "10" which parses as 0x10). Corrected
all IDs to match hardware: 0x10, 0x11, 0x13, 0x14, 0x15, 0x50, 0x51, 0x55.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>