0280a2fad1 feat: page-based navigation shell + Tests page wizard
Replace the monolithic MainWindow with a SelectedPage-driven shell
(Dashboard / Pump / Bench / Tests / Results / Settings). The Tests
page gets the Plan -> Preconditions -> Running -> Done wizard from
ui-structure.md \u00a74, backed by a 7-item precondition gate and
shared sub-views (PhaseCardView / TestSectionView / GraphicIndicatorView)
extracted from the now-deleted monolithic TestPanelView.

New VMs / views:
- Tests wizard: TestPreconditions, PhaseCard, GraphicIndicator,
  TestSection, TestPlan, TestRunning, TestDone
- Dashboard panels: DashboardConnection, DashboardReadings,
  DashboardAlarms, InterlockBanner, ResultHistory
- Pump / bench panels: PumpIdentificationPanel, PumpLiveData,
  UnlockPanel, BenchDriveControl, BenchReadings, RelayBank,
  TemperatureControl, DtcList, AuthGate
- Dialogs: generic ConfirmDialog, UserManageDialog, UserPromptDialog

Supporting changes:
- IsOilPumpOn exposed on MainViewModel for precondition evaluation
- RequiresAuth added to TestDefinition (XML round-trip)
- BipStatusDefinition + CompletedTestRun models
- ~35 new Test.* localization keys (en + es)
- Settings moved from modal dialog to full page
- Pause / Retry / Skip stubs in TestRunningView; full spec in
  docs/gap-test-running-controls.md for follow-up implementation
- docs/ui-structure.md captures the wizard design

Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
2026-04-18 13:11:34 +02:00
4891eb6812 feat: redesign bench calibration (factor/offset), add Ttank/P2 displays, fix sensor calibration
- Replace P1-P6 rational transfer function with factor/offset model for bench params
- Add explicit rx/tx direction flags in bench XML configuration
- Add T.Tank (BenchTemp) and P2 (AnalogSensor2) to temperature/pressure display
- Apply SensorConfiguration calibration to pressure channels, fix empty sensors.xml fallback
- Add live value labels to flowmeter charts
- Hide pump live values and PSG encoder standalone label
- Add K-Line connection state model, improve KWP service and status displays
- Restructure .claude/skills into subdirectory format

Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
2026-04-14 21:25:30 +02:00
e343006f45 feat: restore bench section UI with controls, PID RPM ramp, flowmeter charts, and fix CAN IDs
Restore the full bench control panel from the old source with MVVM architecture:

- Two-column left panel layout: bench info displays (RPM with target/voltage,
  temps, pressures, Q-flow, pump live values) and user commands (direction
  toggle, start/stop with RPM popup and quick-select buttons, oil pump toggle,
  turn downcounter with CAN send)
- PID RPM ramp controller (BenchPidController) with bumpless startup,
  anti-windup, and derivative-on-measurement for smooth motor speed transitions
- Real-time flowmeter charts (LiveChartsCore) for Q-Delivery and Q-Over
  with tolerance band overlays
- Bench/pump CAN liveness detection in PcanAdapter (receive-only IDs)
- K-Line connection status indicator (placeholder)
- Periodic relay bitmask sender (~21ms) and ElectronicMsg keepalive start
  on CAN connect, pump sender starts immediately on pump load

Fix critical CAN message ID bug: default bench XML values were incorrectly
converted from old source (decimal-notation hex parsed as actual hex digits,
e.g. "10" -> "A" instead of keeping "10" which parses as 0x10). Corrected
all IDs to match hardware: 0x10, 0x11, 0x13, 0x14, 0x15, 0x50, 0x51, 0x55.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-11 14:24:59 +02:00
6e1b929e2f initial commit 2026-04-11 12:45:18 +02:00