69bfda54e1 feat: redesign Bench page with Fluent card layout and radial advance monitor
Three-column layout replacing the old HMI grid:
- BenchRpmCommandCard: inline numeric input, 2×4 preset grid, Start/Stop
- BenchActuatorsCard: direction toggle, oil pump, temperature PID, misc relays
  with FluentStateToggle showing checked state via AccentFillColor
- BenchLiveDataCard: 2×5 KPI tiles (RPM, P1, P2, Q-Delivery, Q-Over, temps)
- BenchChartsCard: 2×2 compact chart grid (Delivery, Over, P1, P2)
- AdvanceMonitorCard: RadialAngleGauge custom FrameworkElement + PSG/INJ readouts,
  Δ° lock offset input, Zero PSG / Zero INJ buttons

Supporting changes:
- AngleDisplayViewModel: promote _currentManualDegrees, _isLockSet to
  [ObservableProperty]; add PsgRelativeDegrees, InjEncoderDegreesValue,
  TargetLockAngle, IsRunningMode (29/31 hysteresis); computed PrimaryGaugeAngle,
  TargetAngleForGauge, SecondaryGaugeAngle
- BenchControlViewModel: add IsDirectionLeft computed property,
  SetDirectionRightCommand, SetDirectionLeftCommand, ApplyRpmCommand
- FlowmeterChartView: add IsCompact DP (false default) for 90px compact height
- Styles.xaml: add IsChecked trigger to FluentStateToggle (accent fill + white text)
- Strings.en/es.xaml: add all new card and actuator string keys

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-20 17:45:59 +02:00
70be693116 feat: redesign Pump page with Fluent card layout, bottom snackbar, and RPM chart
- Replace sub-nav + HiddenTabsTabControl with 3-column Fluent card layout:
  PumpCommandsCard (vertical ME/FBKW/PreIn sliders) + DfiCalibrationCard /
  PumpLiveDataCard (KPI tiles + RPM rolling chart + redesigned status bytes) /
  PumpIdentificationCard + DtcCard
- Add PumpTopStripView: pump selector, model badge, CAN + K-Line chips
- Move immobilizer unlock to MainWindow bottom snackbar (UnlockSnackbarView):
  auto-close on success after 3 s, persist on failure with manual Dismiss
- Redesign StatusDisplayView to 2×8 rounded 28px tiles with bit index + tooltip
- Add NullToVisibilityConverter; add SnackbarShell, PumpCard, and related styles
- Delete obsolete views: UnlockProgressDialog, UnlockPanelView,
  PumpIdentificationPanelView, PumpLiveDataView, DfiManageView,
  DtcListView, PumpControlView
- PumpPageViewModel: remove PumpSubPage enum, add RpmChart wired to Root.PumpRpm

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-20 14:03:47 +02:00
197e9d1775 feat: redesign dashboard with Fluent KPI tiles, connection strip, and devices column
- Replace LCD-style readings with a 3×2 KPI tile grid (Fluent card surfaces, 52pt values)
- Add persistent top connection strip with horizontal chips + pump name badge
- Add elapsed test timer (DispatcherTimer, mm:ss) to Test Summary card
- Restyle Test Summary and Active Alarms with Fluent brushes/iconography
- Add Devices column (CAN / K-Line / Bench tiles) between KPI grid and test/alarms
  - Enumerates attached PCAN USB channels via PCAN_ATTACHED_CHANNELS API
  - Enumerates FTDI K-Line adapters via existing FtdiInterface helpers
  - Click to connect/disconnect; confirmation dialog when session active or test running
  - Hover tint: blue = will connect, red = will disconnect; Bench row is read-only stub
- Extend ICanService with SelectedChannel + EnumerateAttachedChannels()
- Expose IKwpService.ConnectedPort for active session device tracking
- Add DeviceRow button style with MultiDataTrigger hover colour logic
- Add 30+ new localization keys (ES + EN) for KPI labels, devices, confirmations

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-19 22:25:00 +02:00
0280a2fad1 feat: page-based navigation shell + Tests page wizard
Replace the monolithic MainWindow with a SelectedPage-driven shell
(Dashboard / Pump / Bench / Tests / Results / Settings). The Tests
page gets the Plan -> Preconditions -> Running -> Done wizard from
ui-structure.md \u00a74, backed by a 7-item precondition gate and
shared sub-views (PhaseCardView / TestSectionView / GraphicIndicatorView)
extracted from the now-deleted monolithic TestPanelView.

New VMs / views:
- Tests wizard: TestPreconditions, PhaseCard, GraphicIndicator,
  TestSection, TestPlan, TestRunning, TestDone
- Dashboard panels: DashboardConnection, DashboardReadings,
  DashboardAlarms, InterlockBanner, ResultHistory
- Pump / bench panels: PumpIdentificationPanel, PumpLiveData,
  UnlockPanel, BenchDriveControl, BenchReadings, RelayBank,
  TemperatureControl, DtcList, AuthGate
- Dialogs: generic ConfirmDialog, UserManageDialog, UserPromptDialog

Supporting changes:
- IsOilPumpOn exposed on MainViewModel for precondition evaluation
- RequiresAuth added to TestDefinition (XML round-trip)
- BipStatusDefinition + CompletedTestRun models
- ~35 new Test.* localization keys (en + es)
- Settings moved from modal dialog to full page
- Pause / Retry / Skip stubs in TestRunningView; full spec in
  docs/gap-test-running-controls.md for follow-up implementation
- docs/ui-structure.md captures the wizard design

Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
2026-04-18 13:11:34 +02:00
37d099cdbd feat: add Ford VP44 unlock progress dialog, K-Line fast unlock, localization, safety dialogs, and settings
Unlock progress UI:
- UnlockProgressDialog with dark-themed progress ring, phase indicator, elapsed
  time, and cancel/close buttons (non-modal, draggable borderless window)
- UnlockProgressViewModel with event-driven progress tracking via IUnlockService
- Triggers on pump selection (manual or K-Line auto-detect), not test start

UnlockService rewrite:
- Persistent CAN senders that outlive the unlock sequence (StopSenders on pump change)
- Concurrent K-Line fast unlock: awaits session Connected, sends RAM timer shortcut
  ({02 88 02 03 A8 01 00}), verifies via CAN TestUnlock before skipping wait
- Fix Type 1 verification (Value == 0 means unlocked, was inverted)

K-Line fast unlock support:
- IKwpService.TryFastUnlockAsync / KwpService implementation

Additional features:
- ILocalizationService with ES/EN resource dictionaries and runtime switching
- Safety dialogs: VoltageWarning, OilPumpConfirm, RpmSafetyWarning
- SettingsDialog for app configuration
- BenchService enhancements, ConfigurationService improvements, PDF report updates
- All UI strings localized via DynamicResource

Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
2026-04-16 13:22:48 +02:00
4891eb6812 feat: redesign bench calibration (factor/offset), add Ttank/P2 displays, fix sensor calibration
- Replace P1-P6 rational transfer function with factor/offset model for bench params
- Add explicit rx/tx direction flags in bench XML configuration
- Add T.Tank (BenchTemp) and P2 (AnalogSensor2) to temperature/pressure display
- Apply SensorConfiguration calibration to pressure channels, fix empty sensors.xml fallback
- Add live value labels to flowmeter charts
- Hide pump live values and PSG encoder standalone label
- Add K-Line connection state model, improve KWP service and status displays
- Restructure .claude/skills into subdirectory format

Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
2026-04-14 21:25:30 +02:00
4964806de1 feat: move test buttons to right panel, add user auth dialog for reports
Move Start/Stop/Report buttons from the middle panel to the top of
TestPanelView (automated tests section), matching the old application
layout. Remove inline Operator/Client text fields — operator identity
now comes from a UserCheckDialog (username/password) shown before the
existing ReportDialog. Add credential storage to ConfigurationService.

Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
2026-04-11 16:41:20 +02:00
d34e81163a feat: add AngleDisplay MVVM UserControl for advance monitoring
Refactors the old AngleDisplay code-behind into a clean MVVM implementation
with AngleDisplayViewModel (PSG/INJ/Manual encoder angles, zero references,
lock angle calculation with tolerance color coding) and a pure XAML view.
Wires LockAngleFaseReady and PsgModeFaseReady test phase events.

Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
2026-04-11 15:16:15 +02:00
e343006f45 feat: restore bench section UI with controls, PID RPM ramp, flowmeter charts, and fix CAN IDs
Restore the full bench control panel from the old source with MVVM architecture:

- Two-column left panel layout: bench info displays (RPM with target/voltage,
  temps, pressures, Q-flow, pump live values) and user commands (direction
  toggle, start/stop with RPM popup and quick-select buttons, oil pump toggle,
  turn downcounter with CAN send)
- PID RPM ramp controller (BenchPidController) with bumpless startup,
  anti-windup, and derivative-on-measurement for smooth motor speed transitions
- Real-time flowmeter charts (LiveChartsCore) for Q-Delivery and Q-Over
  with tolerance band overlays
- Bench/pump CAN liveness detection in PcanAdapter (receive-only IDs)
- K-Line connection status indicator (placeholder)
- Periodic relay bitmask sender (~21ms) and ElectronicMsg keepalive start
  on CAN connect, pump sender starts immediately on pump load

Fix critical CAN message ID bug: default bench XML values were incorrectly
converted from old source (decimal-notation hex parsed as actual hex digits,
e.g. "10" -> "A" instead of keeping "10" which parses as 0x10). Corrected
all IDs to match hardware: 0x10, 0x11, 0x13, 0x14, 0x15, 0x50, 0x51, 0x55.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-11 14:24:59 +02:00
6e1b929e2f initial commit 2026-04-11 12:45:18 +02:00