Commit Graph

3 Commits

Author SHA1 Message Date
197e9d1775 feat: redesign dashboard with Fluent KPI tiles, connection strip, and devices column
- Replace LCD-style readings with a 3×2 KPI tile grid (Fluent card surfaces, 52pt values)
- Add persistent top connection strip with horizontal chips + pump name badge
- Add elapsed test timer (DispatcherTimer, mm:ss) to Test Summary card
- Restyle Test Summary and Active Alarms with Fluent brushes/iconography
- Add Devices column (CAN / K-Line / Bench tiles) between KPI grid and test/alarms
  - Enumerates attached PCAN USB channels via PCAN_ATTACHED_CHANNELS API
  - Enumerates FTDI K-Line adapters via existing FtdiInterface helpers
  - Click to connect/disconnect; confirmation dialog when session active or test running
  - Hover tint: blue = will connect, red = will disconnect; Bench row is read-only stub
- Extend ICanService with SelectedChannel + EnumerateAttachedChannels()
- Expose IKwpService.ConnectedPort for active session device tracking
- Add DeviceRow button style with MultiDataTrigger hover colour logic
- Add 30+ new localization keys (ES + EN) for KPI labels, devices, confirmations

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-19 22:25:00 +02:00
e343006f45 feat: restore bench section UI with controls, PID RPM ramp, flowmeter charts, and fix CAN IDs
Restore the full bench control panel from the old source with MVVM architecture:

- Two-column left panel layout: bench info displays (RPM with target/voltage,
  temps, pressures, Q-flow, pump live values) and user commands (direction
  toggle, start/stop with RPM popup and quick-select buttons, oil pump toggle,
  turn downcounter with CAN send)
- PID RPM ramp controller (BenchPidController) with bumpless startup,
  anti-windup, and derivative-on-measurement for smooth motor speed transitions
- Real-time flowmeter charts (LiveChartsCore) for Q-Delivery and Q-Over
  with tolerance band overlays
- Bench/pump CAN liveness detection in PcanAdapter (receive-only IDs)
- K-Line connection status indicator (placeholder)
- Periodic relay bitmask sender (~21ms) and ElectronicMsg keepalive start
  on CAN connect, pump sender starts immediately on pump load

Fix critical CAN message ID bug: default bench XML values were incorrectly
converted from old source (decimal-notation hex parsed as actual hex digits,
e.g. "10" -> "A" instead of keeping "10" which parses as 0x10). Corrected
all IDs to match hardware: 0x10, 0x11, 0x13, 0x14, 0x15, 0x50, 0x51, 0x55.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-11 14:24:59 +02:00
6e1b929e2f initial commit 2026-04-11 12:45:18 +02:00