Restore the full bench control panel from the old source with MVVM architecture: - Two-column left panel layout: bench info displays (RPM with target/voltage, temps, pressures, Q-flow, pump live values) and user commands (direction toggle, start/stop with RPM popup and quick-select buttons, oil pump toggle, turn downcounter with CAN send) - PID RPM ramp controller (BenchPidController) with bumpless startup, anti-windup, and derivative-on-measurement for smooth motor speed transitions - Real-time flowmeter charts (LiveChartsCore) for Q-Delivery and Q-Over with tolerance band overlays - Bench/pump CAN liveness detection in PcanAdapter (receive-only IDs) - K-Line connection status indicator (placeholder) - Periodic relay bitmask sender (~21ms) and ElectronicMsg keepalive start on CAN connect, pump sender starts immediately on pump load Fix critical CAN message ID bug: default bench XML values were incorrectly converted from old source (decimal-notation hex parsed as actual hex digits, e.g. "10" -> "A" instead of keeping "10" which parses as 0x10). Corrected all IDs to match hardware: 0x10, 0x11, 0x13, 0x14, 0x15, 0x50, 0x51, 0x55. Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
194 lines
8.2 KiB
C#
194 lines
8.2 KiB
C#
using System;
|
|
using System.Windows;
|
|
using CommunityToolkit.Mvvm.ComponentModel;
|
|
using CommunityToolkit.Mvvm.Input;
|
|
using HC_APTBS.Models;
|
|
using HC_APTBS.Services;
|
|
|
|
namespace HC_APTBS.ViewModels
|
|
{
|
|
/// <summary>
|
|
/// ViewModel for manual bench controls: direction toggle, RPM start/stop with
|
|
/// PID ramp, oil pump toggle, and turn downcounter.
|
|
/// Created by <see cref="MainViewModel"/> as a child ViewModel.
|
|
/// </summary>
|
|
public sealed partial class BenchControlViewModel : ObservableObject
|
|
{
|
|
private readonly IBenchService _bench;
|
|
private readonly IConfigurationService _config;
|
|
|
|
// ── Direction ─────────────────────────────────────────────────────────────
|
|
|
|
/// <summary>True when the bench rotates clockwise (right). False for counter-clockwise (left).</summary>
|
|
[ObservableProperty] private bool _isDirectionRight = true;
|
|
|
|
// ── Oil pump ──────────────────────────────────────────────────────────────
|
|
|
|
/// <summary>True when the oil pump relay is energised.</summary>
|
|
[ObservableProperty] private bool _isOilPumpOn;
|
|
|
|
// ── RPM control ───────────────────────────────────────────────────────────
|
|
|
|
/// <summary>True when the bench motor is running (last RPM command > 0).</summary>
|
|
[ObservableProperty] private bool _isBenchRunning;
|
|
|
|
/// <summary>Controls the RPM quick-select popup visibility.</summary>
|
|
[ObservableProperty] private bool _isRpmPopupOpen;
|
|
|
|
/// <summary>Text in the RPM input field.</summary>
|
|
[ObservableProperty] private string _rpmInputText = string.Empty;
|
|
|
|
/// <summary>Last RPM setpoint commanded via PID or direct set.</summary>
|
|
[ObservableProperty] private double _targetRpm;
|
|
|
|
/// <summary>Last voltage sent to the motor CAN parameter.</summary>
|
|
[ObservableProperty] private double _commandVoltage;
|
|
|
|
// ── Counter ───────────────────────────────────────────────────────────────
|
|
|
|
/// <summary>Controls the counter popup visibility.</summary>
|
|
[ObservableProperty] private bool _isCounterPopupOpen;
|
|
|
|
/// <summary>Text in the counter input field.</summary>
|
|
[ObservableProperty] private string _counterInputText = string.Empty;
|
|
|
|
/// <summary>Live counter count-down value read from CAN.</summary>
|
|
[ObservableProperty] private double _benchCounterValue;
|
|
|
|
// ── Constructor ───────────────────────────────────────────────────────────
|
|
|
|
/// <summary>
|
|
/// Creates the bench control ViewModel and subscribes to service events.
|
|
/// </summary>
|
|
/// <param name="benchService">Bench service for RPM, relay, and parameter operations.</param>
|
|
/// <param name="configService">Configuration service for bench parameters.</param>
|
|
public BenchControlViewModel(IBenchService benchService, IConfigurationService configService)
|
|
{
|
|
_bench = benchService;
|
|
_config = configService;
|
|
|
|
_bench.RpmCommandSent += () =>
|
|
{
|
|
TargetRpm = _bench.LastTargetRpm;
|
|
CommandVoltage = _bench.LastCommandVoltage;
|
|
};
|
|
}
|
|
|
|
// ── Direction toggle ──────────────────────────────────────────────────────
|
|
|
|
partial void OnIsDirectionRightChanged(bool value)
|
|
{
|
|
_bench.SetRelay(RelayNames.DirectionRight, value);
|
|
_bench.SetRelay(RelayNames.DirectionLeft, !value);
|
|
}
|
|
|
|
// ── Oil pump toggle ───────────────────────────────────────────────────────
|
|
|
|
partial void OnIsOilPumpOnChanged(bool value)
|
|
{
|
|
_bench.SetRelay(RelayNames.OilPump, value);
|
|
}
|
|
|
|
// ── RPM commands ──────────────────────────────────────────────────────────
|
|
|
|
/// <summary>Opens the RPM quick-select popup.</summary>
|
|
[RelayCommand]
|
|
private void OpenRpmPopup()
|
|
{
|
|
IsRpmPopupOpen = true;
|
|
}
|
|
|
|
/// <summary>
|
|
/// Starts the bench motor at the RPM specified in <see cref="RpmInputText"/>.
|
|
/// Warns the operator if the oil pump is off.
|
|
/// </summary>
|
|
[RelayCommand]
|
|
private void StartBench()
|
|
{
|
|
if (!int.TryParse(RpmInputText, out int rpm) || rpm <= 0) return;
|
|
|
|
// Safety warning if oil pump is not running.
|
|
if (!IsOilPumpOn)
|
|
{
|
|
var result = MessageBox.Show(
|
|
"Oil pump is OFF. Start bench without oil circulation?",
|
|
"Oil Pump Warning",
|
|
MessageBoxButton.YesNo,
|
|
MessageBoxImage.Warning);
|
|
if (result != MessageBoxResult.Yes) return;
|
|
}
|
|
|
|
// Ensure direction relays are set.
|
|
_bench.SetRelay(RelayNames.DirectionRight, IsDirectionRight);
|
|
_bench.SetRelay(RelayNames.DirectionLeft, !IsDirectionRight);
|
|
|
|
_bench.StartRpmPid(rpm);
|
|
IsBenchRunning = true;
|
|
IsRpmPopupOpen = false;
|
|
}
|
|
|
|
/// <summary>
|
|
/// Stops the bench motor via PID stop and clears direction relays.
|
|
/// </summary>
|
|
[RelayCommand]
|
|
private void StopBench()
|
|
{
|
|
_bench.StopRpmPid();
|
|
_bench.SetRelay(RelayNames.DirectionLeft, false);
|
|
_bench.SetRelay(RelayNames.DirectionRight, false);
|
|
IsBenchRunning = false;
|
|
}
|
|
|
|
/// <summary>
|
|
/// Quick-select button handler: sets the RPM input and starts the bench.
|
|
/// </summary>
|
|
/// <param name="rpmString">RPM value as a string from the button content.</param>
|
|
[RelayCommand]
|
|
private void SetQuickRpm(string rpmString)
|
|
{
|
|
RpmInputText = rpmString;
|
|
StartBench();
|
|
}
|
|
|
|
// ── Counter commands ──────────────────────────────────────────────────────
|
|
|
|
/// <summary>Toggles the counter popup visibility.</summary>
|
|
[RelayCommand]
|
|
private void ToggleCounterPopup()
|
|
{
|
|
IsCounterPopupOpen = !IsCounterPopupOpen;
|
|
}
|
|
|
|
/// <summary>
|
|
/// Sends the counter value over CAN and activates the counter relay.
|
|
/// </summary>
|
|
[RelayCommand]
|
|
private void SendCounter()
|
|
{
|
|
if (!int.TryParse(CounterInputText, out int count) || count <= 0) return;
|
|
|
|
// Set the counter parameter value and transmit.
|
|
_bench.SetParameter(BenchParameterNames.Counter, count);
|
|
if (_config.Bench.ParametersByName.TryGetValue(
|
|
BenchParameterNames.Counter, out var counterParam))
|
|
{
|
|
_bench.SendParameters(counterParam.MessageId);
|
|
}
|
|
|
|
// Activate the counter relay.
|
|
_bench.SetRelay(RelayNames.Counter, true);
|
|
}
|
|
|
|
// ── Refresh (called from MainViewModel timer tick) ────────────────────────
|
|
|
|
/// <summary>
|
|
/// Updates live counter readback from CAN.
|
|
/// Called on the UI thread from <see cref="MainViewModel.OnRefreshTick"/>.
|
|
/// </summary>
|
|
public void RefreshFromTick()
|
|
{
|
|