Files
HC_APTBS/ViewModels/BenchControlViewModel.cs
LucianoDev 0280a2fad1 feat: page-based navigation shell + Tests page wizard
Replace the monolithic MainWindow with a SelectedPage-driven shell
(Dashboard / Pump / Bench / Tests / Results / Settings). The Tests
page gets the Plan -> Preconditions -> Running -> Done wizard from
ui-structure.md \u00a74, backed by a 7-item precondition gate and
shared sub-views (PhaseCardView / TestSectionView / GraphicIndicatorView)
extracted from the now-deleted monolithic TestPanelView.

New VMs / views:
- Tests wizard: TestPreconditions, PhaseCard, GraphicIndicator,
  TestSection, TestPlan, TestRunning, TestDone
- Dashboard panels: DashboardConnection, DashboardReadings,
  DashboardAlarms, InterlockBanner, ResultHistory
- Pump / bench panels: PumpIdentificationPanel, PumpLiveData,
  UnlockPanel, BenchDriveControl, BenchReadings, RelayBank,
  TemperatureControl, DtcList, AuthGate
- Dialogs: generic ConfirmDialog, UserManageDialog, UserPromptDialog

Supporting changes:
- IsOilPumpOn exposed on MainViewModel for precondition evaluation
- RequiresAuth added to TestDefinition (XML round-trip)
- BipStatusDefinition + CompletedTestRun models
- ~35 new Test.* localization keys (en + es)
- Settings moved from modal dialog to full page
- Pause / Retry / Skip stubs in TestRunningView; full spec in
  docs/gap-test-running-controls.md for follow-up implementation
- docs/ui-structure.md captures the wizard design

Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
2026-04-18 13:11:34 +02:00

222 lines
9.3 KiB
C#

using System;
using System.Windows;
using CommunityToolkit.Mvvm.ComponentModel;
using CommunityToolkit.Mvvm.Input;
using HC_APTBS.Models;
using HC_APTBS.Services;
using HC_APTBS.ViewModels.Dialogs;
using HC_APTBS.Views.Dialogs;
namespace HC_APTBS.ViewModels
{
/// <summary>
/// ViewModel for manual bench controls: direction toggle, RPM start/stop with
/// PID ramp, oil pump toggle, and turn downcounter.
/// Created by <see cref="MainViewModel"/> as a child ViewModel.
/// </summary>
public sealed partial class BenchControlViewModel : ObservableObject
{
private readonly IBenchService _bench;
private readonly IConfigurationService _config;
// ── Direction ─────────────────────────────────────────────────────────────
/// <summary>True when the bench rotates clockwise (right). False for counter-clockwise (left).</summary>
[ObservableProperty] private bool _isDirectionRight = true;
// ── Oil pump ──────────────────────────────────────────────────────────────
/// <summary>True when the oil pump relay is energised.</summary>
[ObservableProperty] private bool _isOilPumpOn;
// ── RPM control ───────────────────────────────────────────────────────────
/// <summary>True when the bench motor is running (last RPM command > 0).</summary>
[ObservableProperty] private bool _isBenchRunning;
/// <summary>Controls the RPM quick-select popup visibility.</summary>
[ObservableProperty] private bool _isRpmPopupOpen;
/// <summary>Text in the RPM input field.</summary>
[ObservableProperty] private string _rpmInputText = string.Empty;
/// <summary>Last RPM setpoint commanded via PID or direct set.</summary>
[ObservableProperty] private double _targetRpm;
/// <summary>Last voltage sent to the motor CAN parameter.</summary>
[ObservableProperty] private double _commandVoltage;
// ── Counter ───────────────────────────────────────────────────────────────
/// <summary>Controls the counter popup visibility.</summary>
[ObservableProperty] private bool _isCounterPopupOpen;
/// <summary>Text in the counter input field.</summary>
[ObservableProperty] private string _counterInputText = string.Empty;
/// <summary>Live counter count-down value read from CAN.</summary>
[ObservableProperty] private double _benchCounterValue;
// ── Constructor ───────────────────────────────────────────────────────────
/// <summary>
/// Creates the bench control ViewModel and subscribes to service events.
/// </summary>
/// <param name="benchService">Bench service for RPM, relay, and parameter operations.</param>
/// <param name="configService">Configuration service for bench parameters.</param>
public BenchControlViewModel(IBenchService benchService, IConfigurationService configService)
{
_bench = benchService;
_config = configService;
_bench.RpmCommandSent += () =>
Application.Current.Dispatcher.Invoke(() =>
{
TargetRpm = _bench.LastTargetRpm;
CommandVoltage = _bench.LastCommandVoltage;
});
}
// ── Direction toggle ──────────────────────────────────────────────────────
partial void OnIsDirectionRightChanged(bool value)
{
_bench.SetRelay(RelayNames.DirectionRight, value);
_bench.SetRelay(RelayNames.DirectionLeft, !value);
}
// ── Oil pump toggle ───────────────────────────────────────────────────────
partial void OnIsOilPumpOnChanged(bool value)
{
// Show confirmation dialog when turning oil pump ON (WAcceptOilTurnOn equivalent).
if (value)
{
var vm = new OilPumpConfirmViewModel();
var dlg = new OilPumpConfirmDialog(vm) { Owner = Application.Current.MainWindow };
dlg.ShowDialog();
if (!vm.Accepted)
{
// Revert without re-triggering this handler.
_isOilPumpOn = false;
OnPropertyChanged(nameof(IsOilPumpOn));
return;
}
}
_bench.SetRelay(RelayNames.OilPump, value);
}
// ── RPM commands ──────────────────────────────────────────────────────────
/// <summary>Opens the RPM quick-select popup.</summary>
[RelayCommand]
private void OpenRpmPopup()
{
IsRpmPopupOpen = true;
}
/// <summary>
/// Starts the bench motor at the RPM specified in <see cref="RpmInputText"/>.
/// Shows a safety warning dialog if the oil pump is off.
/// </summary>
[RelayCommand]
private void StartBench()
{
if (!int.TryParse(RpmInputText, out int rpm) || rpm <= 0) return;
// Safety warning if oil pump is not running (WCareOnRpmOn equivalent).
if (!IsOilPumpOn)
{
var vm = new RpmSafetyWarningViewModel();
var dlg = new RpmSafetyWarningDialog(vm) { Owner = Application.Current.MainWindow };
dlg.ShowDialog();
switch (vm.Result)
{
case RpmSafetyResult.Cancel:
return;
case RpmSafetyResult.ProceedWithOil:
IsOilPumpOn = true;
break;
case RpmSafetyResult.ProceedWithoutOil:
// Operator accepted the risk.
break;
}
}
// Ensure direction relays are set.
_bench.SetRelay(RelayNames.DirectionRight, IsDirectionRight);
_bench.SetRelay(RelayNames.DirectionLeft, !IsDirectionRight);
_bench.StartRpmPid(rpm);
IsBenchRunning = true;
IsRpmPopupOpen = false;
}
/// <summary>
/// Stops the bench motor via PID stop and clears direction relays.
/// </summary>
[RelayCommand]
private void StopBench()
{
_bench.StopRpmPid();
_bench.SetRelay(RelayNames.DirectionLeft, false);
_bench.SetRelay(RelayNames.DirectionRight, false);
IsBenchRunning = false;
}
/// <summary>
/// Quick-select button handler: sets the RPM input and starts the bench.
/// </summary>
/// <param name="rpmString">RPM value as a string from the button content.</param>
[RelayCommand]
private void SetQuickRpm(string rpmString)
{
RpmInputText = rpmString;
StartBench();
}
// ── Counter commands ──────────────────────────────────────────────────────
/// <summary>Toggles the counter popup visibility.</summary>
[RelayCommand]
private void ToggleCounterPopup()
{
IsCounterPopupOpen = !IsCounterPopupOpen;
}
/// <summary>
/// Sends the counter value over CAN and activates the counter relay.
/// </summary>
[RelayCommand]
private void SendCounter()
{
if (!int.TryParse(CounterInputText, out int count) || count <= 0) return;
// Set the counter parameter value and transmit.
_bench.SetParameter(BenchParameterNames.Counter, count);
if (_config.Bench.ParametersByName.TryGetValue(
BenchParameterNames.Counter, out var counterParam))
{
_bench.SendParameters(counterParam.MessageId);
}
// Activate the counter relay.
_bench.SetRelay(RelayNames.Counter, true);
}
// ── Refresh (called from MainViewModel timer tick) ────────────────────────
/// <summary>
/// Updates live counter readback from CAN.
/// Called on the UI thread from <see cref="MainViewModel.OnRefreshTick"/>.
/// </summary>
public void RefreshFromTick()
{
BenchCounterValue = _bench.ReadBenchParameter(BenchParameterNames.BenchCounter);
}
}
}